Laboratory Analyser
| Type | Fully Automated Analysis system |
| Throughput | 140 tests per hour |
| Analytical Methods | End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more |
| Assay Modules | Over 200 modules |
| Type | Fully Automated Random Access System |
| Throughput | Reagent 1 : 400 test/hr Reagent 2 : 600 test/hr With ISE : 400 test/hr |
| Analytical Methods | End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc. |
| Assay Modules | 80 modules |
| Type | Fully Automatic Random Access system |
| Throughput | 120 tests/hour |
| Assay Modules | Up to 26 Assays |
| Sample slots | 9 |
| Number of channels | Single channel |
| Test parameters | PT [Prothrombin Time] APTT [Activated Partial Thromboplastin Time] TT [Thrombin Time] FBG [Fibrinogen Concentration] Clotting Factors |
| Measurement method | Photometric analysis |
| Display | Back-illuminated LCD |
| Measurement range | 3 % ~ 18 % |
| Testing parameters | Precision (CV) < 3 % Accuracy (V) < 1.5 % |
| Sample type | Venous blood (EDTA anticoagulation), Peripheral finger blood |
| Sample volume | 5 µl whole blood for each sample |
| Type | Fully automated 3-part differential system |
| Throughput | 60 samples/hr |
| Principle of Operation | |
| Testing Parameters | WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT. |
| Type | Fully automated 3-part differential system |
| Throughput | 60 samples/hr |
| Principle of Operation | |
| Testing Parameters | WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT. |
| Type | Fully automated 3-part differential system |
| Throughput | 60 samples/hr |
| Principle of Operation | |
| Testing Parameters | WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT. |
| Type | Fully automated 5-part differential system |
| Throughput | 60 samples/hr |
| Principle of Operation | |
| Testing Parameters | WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams. |
| Type | Fully automated 3-part differential system |
| Throughput | 30 samples/hr |
| Principle of Operation | Impedance, SFT method |
| Testing Parameters |
| Type | Fully automated 5-part differential system |
| Throughput | 60 samples/hr |
| Principle of Operation | Impedance, Colorimetry |
| Testing Parameters |
| Method | RGB Tricolor test |
| Test mode | Single-step test |
| Strip compliance | 8, 10, 11, 12, 14 parameter test strips |
| Memory | Stores up to 500 records |
Copyright © Labopark Scientific Inc. All Rights Reserved