Critical Care
| Patient range | Adult, pediatric, neonate |
| NIBP Measurement method | Oscillometric |
| NIBP Measurement range | 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg) |
| NIBP Measurement mode | Arm Measurement |
| Temperature Range | 37°C to 42°C |
| Temperature Accuracy | ± 0.5°C |
| Warm-up Time | < 45 s (20°C to 36°C) |
| Power Consumption | 250 VA |
| Temperature Range | 37°C to 42°C |
| Temperature Accuracy | ± 1.0°C |
| Warm-up Time | < 45 s (20°C to 36°C) |
| Power Consumption | 80 VA |
| Display | 12.1” LCD display |
| Ultrasound frequency | 1024 (1 ± 10%) kHz |
| Max output intensity | < 10 MW/cm2 |
| FHR measurement range | 30 bpm ~ 240 bpm |
| Display | 7-inch screen |
| Waveform | Biphasic |
| Manual with Sync mode | 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules |
| AED mode | Auto analyze and charge x 3 with programmable auto energy level selection. |
| Waveform | Biphasic |
| Energy Sequence | 150 J, 200 J |
| Analysis Time | 9 seconds |
| Audio Indications | 20 distinct voice instructions |
| Display | OLED 160 x 128 dot matrix display |
| Storage | Built-in TF card storage for up to 2 GB |
| Standard Sensitivity | 10 mm/mV ± 5% |
| Sensitivity Shift | ≤ ± 10% |
| Control System | Air-temp control, Skin-temp control & Humidity control |
| Display | LED display |
| Air Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Baby Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Control System | Air-temp control & Skin-temp control |
| Display | LED display |
| Air Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Baby Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
| Control System | Air-temp control |
| Display | LED display |
| Air Temperature Control range | 25°C ~ 37°C |
| Baby Temperature Control range |
| Channel | Single channel infusion |
| Volume (VTBI) | 1 ml ~ 9999.9 ml ( 0.1 ml increment) |
| Accuracy | Flow rate: ≤ ± 3 % Mechanical: ≤ ± 2 % |
| KVO Rate | 1 ml/h (1 ml/h ~ 300 ml/h) 3 ml/h (greater than 300 ml/h) |
| Channel | Single channel infusion |
| Infusion Volume | 0 ml ~ 9999 ml ( 0.1ml increment) |
| Infusion Rate | 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment) |
| KVO Rate | 0.01 ml/h – 5 ml/h |
| Tidal Volume | 20 ml ~ 500 ml |
| Standard Ventilation Mode | VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH |
| Application | Adult/ Pediatric Invasive |
| Pressure Range | 5 mbar ~ 80 mbar |
| Tidal Volume | 10 ml ~ 300 ml |
| Standard Ventilation Mode | CMV, IMV, CPAP, Manual |
| Application | Pediatric |
| Inspiratory Flow | 3 L/min ~ 20 L/min |
| Tidal Volume | 20 ml ─ 2500 ml |
| Configurations | Trolley or Ceiling Pendant |
| Respiratory Rate | 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) 4 bpm ─ 100 bpm ( VCV/PCV/PRVC) |
| Psupport | 0 kPa ─ 6 kPa |
| Control System | Microprocessor based temperature control system |
| Control Modes | Preheat, Manual and Skin-temp mode |
| Manual : Heater output | 0-100%, 10% increments |
| Skin-temp : Control range | 25 °C ~ 37 °C |
| Vital Parameters |
|
||||||
| Display | 240 x 320 dot matrix colour TFT | ||||||
| NIBP Measurement range | Adult: 30-255 mmHg Paediatric: 30-160 mmHg | ||||||
| NIBP Mode | Auto, Manual, STAT |
| Vital Parameters | 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP) |
| NIBP Measurement range | Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg |
| NIBP Mode | Manual, Auto |
| NIBP Parameters | Sys, Dia, MAP |
| Standard Parameter | 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR |
| Patient Groups | Neonate, Pediatric, Adults |
| Trace | 9 waveform (ECG,SpO2, RESP) |
| ECG Lead Mode | 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL |
| Light Source | 8 Blue LED lights |
| Wavelength | 450 to 475nm |
| LED Lamp-life | 1,00,000 hours |
| Intensity Control | Low : 25 ~ 35 μW /cm2/nm High : 35 ~ 55 μW /cm2/nm |
| Type | Adult |
| Stroke volume | 800 ml |
| Resuscitator volume | 1630 ml |
| Bag reservoir volume | 2000 ml |
| Type | Pediatric |
| Stroke volume | 350 ml |
| Resuscitator volume | 680 ml |
| Bag reservoir volume | 1600 ml |
| Type | Neonatal |
| Stroke volume | 150 ml |
| Resuscitator volume | 250 ml |
| Bag reservoir volume | 600 ml |
| KVO Rate | 0.1 – 5ml/h (steps : 0.1ml/h) |
| Injection Compliance | Adaptable for 5 syringe sizes |
| Preset Volume Range | 0.1 ml – 1999.9 ml |
| Occlusion System | 3-level alarming system |
| Channel | Single channel infusion |
| Volume (VTBI) | 0 ml – 9999 ml |
| Injection Compliance | Adaptable for 6 syringe sizes |
| Accuracy | ≤ ±2 % |
| Channel | Dual channel infusion |
| Volume (VTBI) | 0.1 ml – 1999.9 ml |
| Injection Compliance | Adaptable for 10 syringe sizes |
| Accuracy | ≤ ± 3 % |
| Tidal Volume | 0 ml – 1500 ml |
| Gas Supply | O2, 0.28 to 0.6 MPa |
| Ventilation Modes | A/C, SIMV, SPONT, Manual, VCV+SIGH |
| Respiratory Rate | 4 bpm – 40 bpm (SIMV) 4 bpm – 99 bpm (A/C) |